首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   144篇
  免费   0篇
化学   138篇
物理学   6篇
  2019年   1篇
  2017年   1篇
  2016年   3篇
  2015年   5篇
  2014年   1篇
  2013年   5篇
  2012年   4篇
  2011年   12篇
  2010年   9篇
  2009年   5篇
  2008年   5篇
  2007年   16篇
  2006年   11篇
  2005年   4篇
  2004年   12篇
  2003年   7篇
  2002年   11篇
  2001年   9篇
  2000年   10篇
  1999年   4篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1994年   3篇
  1993年   3篇
排序方式: 共有144条查询结果,搜索用时 15 毫秒
71.
Sonication procedures are generally used prior to field flow fractionation (FFF) separation in order to produce suspensions without aggregates. Yeast cells manufactured in active dry wine yeast (ADWY) were placed in an ultrasound water bath in order to disrupt possible clumps and to obtain a single-cell suspension to be used in optimal conditions during fermentation processes. In order to determine whether this sample preparation procedure meets absolute needs, different yeast samples before and after sonication were analysed by two field flow fractionation techniques. It is shown that 2 min of sonication in the sample preparation process is sufficient to obtain an optimal dispersion of the yeast cells, that is, without critical percentage of aggregates. To demonstrate this effect, photographs of the yeast cell suspensions were performed with non-sonicated and sonicated yeast sample dispersion. The resulting data are compared with the elution profiles obtained from the two different FFF techniques. It is demonstrated that fractogram profiles prove the effectiveness of sonication methodologies.  相似文献   
72.
A headspace-solid-phase microextraction (HS-SPME) coupled to gas chromatography-ion trap mass spectrometry (GC-IT-MS) method is proposed for the analysis of furan in different heat-treated carbohydrate-rich food samples. The extraction efficiency of six commercially available fibres was evaluated and it was found that a 75mum carboxen/polydimethylsiloxane coating was the most suitable for the extraction of the furan. Parameters affecting the efficiency of HS-SPME procedure such as extraction temperature and time, ionic strength, headspace and aqueous volume ratio (V(h)/V(w)), desorption temperature and time, were optimized. Quality parameters were established using spiked water and food samples. Linearity ranged between 0.02 and 0.5ngg(-1) and run-to-run and day-to-day precisions for food samples were lower than 6% and 10%, respectively. The limit of detection (LOD) of the method is sample dependent and ranged from 8 to 70pgg(-1), while the limit of quantification is from 30 to 250pgg(-1). Isotope dilution using furan-d(4) is proposed for furan determination providing similar results to those obtained by standard addition with internal standard (US Food and Drug Administration method). The developed HS-SPME-GC-IT-MS method was applied to the analysis of furan in different Spanish food samples from a local market, and concentrations ranging from 0.17 to 2279ngg(-1) were found.  相似文献   
73.
In complicated environmental or biological systems, the fluxes of chemical species at a consuming interface, like an organism or an analytical sensor, involve many coupled chemical and diffusion processes. Computation of such fluxes thus becomes difficult. The present paper describes an approximate approach, based on the so-called reaction layer concept, which enables one to obtain a simple analytical solution for the steady-state flux of a metal ion at a consuming interface, in the presence of many ligands, which are in excess with respect to the test metal ion. This model can be used for an unlimited number of ligands and complexes, without limit for the values of the association/dissociation rate constants or diffusion coefficients. This approximate solution is compared with a rigorous approach for the computation of the fluxes based on an extension of a previously published method (J. Galceran, J. Puy, J. Salvador, J. Cecília, F. Mas and J. L. Garcés, Phys. Chem. Chem. Phys., 2003, 5, 5091-5100). The comparison is performed for a very wide range of the key parameters: rate constants and diffusion coefficients, equilibrium constants and ligand concentrations. Their combined influence is studied in the whole domain of fully labile to non-labile complexes, via two combination parameters: the lability index, L, and the reaction layer thickness, mu. The results show that the approximate solution provides accurate results in most cases. However, for particular combinations of metal complexes with specific values of L or mu, significant differences between the approximate and rigorous solutions may occur. They are evaluated and discussed. These results are important for three reasons: (i) they enable the use of the approximate solution in a fully reliable manner, (ii) when present, the differences between approximate and rigorous solution are largely due to the coupling of chemical reactions, whose importance can thus be estimated, (iii) due to its simple mathematical expression, the individual contribution of each metal species to the overall flux can be computed.  相似文献   
74.
A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.  相似文献   
75.
Fragmentation studies using both an ion-trap mass analyzer and a hybrid quadrupole time-of-flight (Q-TOF) mass spectrometer were performed in order to establish the fragmentation pathways of organic molecules. A general strategy combining MSn data (n = 1-4) in an ion-trap analyzer with tandem mass spectrometry and in-source collision-induced dissociation tandem mass spectrometry (CID MS/MS) in a Q-TOF instrument was applied. The MSn data were used to propose a tentative fragmentation pathway following genealogical relationships. When several assignments were possible, MS/MS and in-source CID MS/MS (Q-TOF) allowed the elemental compositions of the fragments to be confirmed. Quaternary ammonium herbicides (quats) were used as test compounds and their fragmentation pathways were established. The elemental composition of the fragments was confirmed using the TOF analyzer with relative errors <0.0023 Da. Some fragments previously reported in the literature were reassigned taking advantage of the high mass resolution and accuracy of the Q-TOF instrument, which made it possible to solve losses where nitrogen was involved.  相似文献   
76.
Eighteen positional isomers of chlorophenols were separated by capillary electrophoresis (CE) and detected on-line by electrospray ionization ion-trap mass spectrometry (MS). Conditions for the coupling of CE to MS, e.g., the concentration of carrier electrolyte, the sheath liquid composition and the sheath gas flow-rate were optimized. Diethylmalonic acid (5 mM) at pH 7.25 and isopropanol-250 mM dimethylamine (80:20) as sheath liquid were used. The activation parameters for ion-trap mass spectrometric analysis of chlorophenols were optimized. The mass spectra, obtained for all the analytes, revealed that the [M-H]- ion was the base peak for all chlorophenols. Moreover, conditions for CE-MS-MS detection were established and [M-H-HCl]- ions were detected.  相似文献   
77.
J. Galceran  C. Huidobro  G. Alberti 《Talanta》2007,71(4):1795-1803
Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) is a recently suggested electroanalytical technique designed for the determination of the free concentration of heavy metals (such as Zn, Cd or Pb) which is here developed and applied to seawater samples. A key improvement for the implementation of AGNES with complex matrices is the development of a new blank, called the shifted blank (presented in this work for the first time), which can be applied to the same sample where the measurement is intended. The careful selection of the required parameters for the determination of the free Zn concentration (or activity) at the nanomolar level is described in detail. The methodology has been validated with a synthetic solution containing Zn and nitrilotriacetic acid (NTA) and then applied, as a first case, to two coastal seawater samples taken close to Barcelona and Tarragona (Catalonia, North-Eastern Spain) finding values in the range of 1-3 nM, representing around 25% of total Zn. This technique can, in the near future, be crucial in helping to elucidate the role of the free zinc(II) concentration in natural waters.  相似文献   
78.
The penetration of metal complexes into the resin layer of DGT (diffusive gradients in thin films) devices greatly influences the measured metal accumulation, unless the complexes are either totally inert or perfectly labile. Lability criteria to predict the contribution of complexes in DGT measurements are reported. The key role of the resin thickness is highlighted. For complexes that are partially labile to the DGT measurement, their dissociation inside the resin domain is the main source of metal accumulation. This phenomenon explains the practical independence of the lability degree of a complex in a DGT device with respect to the ligand concentration. Transient DGT regimes, reflecting the times required to replenish the gel and resin domains up to the steady-state profile of the complex, are also examined. Low lability complexes (lability degree between 0.1 and 0.2) exhibit the longest transient regimes and therefore require longer deployment times to ensure accurate DGT measurements.  相似文献   
79.
The dynamic technique of diffusive gradients in thin films (DGT), that measures metal speciation in situ, has found wide environmental application. Simple interpretation of the metal accumulation in terms of a solution concentration has assumed that trace metals do not penetrate beyond the surface of the binding layer, but penetration, although theoretically discussed has not yet been directly measured. Multiple binding layers were used to enable analysis of different depths of a DGT binding phase (Chelex-100 or iminodiacetate resins). In simple metal solution (no ligand) at pH 7, metal penetration to the back layer was low and similar for all metals. However, at lower pH up to 42% of an individual metal accumulated in the back resin layer. This was most noticeable for Mn at pH 4 and 5, but Cd and Co were also affected at pH 4. These results were consistent with rate limited binding, particularly for Mn. A kinetic model successfully fitted the data and allowed derivation of a binding rate constant and the mean distance that metals penetrate into a resin gel (λM). Only for Mn, Co and Cd were experimentally derived λM values greater than the diameter of a Chelex-100 resin bead. For most situations, then, the penetration into the binding layer is negligible and binding of trace metal ions can be regarded as instantaneous, validating the simple use and interpretation of DGT. For weakly binding metals at low pH the slower binding allows penetration, which may affect the DGT measurement.  相似文献   
80.
Alechaga É  Moyano E  Galceran MT 《The Analyst》2012,137(10):2486-2494
A method based on ultra-high performance liquid chromatography (UHPLC) is proposed for the determination of chloramphenicol (CAP), its related compounds, thiamphenicol (TAP) and florfenicol (FF), and the polar metabolite florfenicol-amine (FFA), in animal-derived foods (chicken and pork meat, fish, prawns and honey). For the retention of FFA and its simultaneous analysis with the parent compounds a phenyl-hexyl column is proposed. A fast separation is achieved in less than 2 minutes using a methanol : acetic acid-ammonium acetate buffer (5 mM, pH 5) and gradient elution. Under these conditions, the FFA is retained at more than twice the dead volume, as recommended by the legislation. For the coupling with mass spectrometry, heated-electrospray (H-ESI) is used as ionisation source improving vaporization efficiency. To prevent interferences using selected-reaction monitoring (SRM) both quantitation and confirmation transitions were carefully selected. Two different sample treatments based on solid-phase extraction with mixed-mode cartridges for fish and meat products and hydrophilic-lipophilic-balanced cartridges for honey are proposed, providing limits of quantitation (LOQs) below μg kg(-1) level.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号